STI turns “it sounds private” into a number. Here is what it measures, why open-plan offices fail it, and where an acoustic pod fits.
Why “it’s a bit noisy” is the wrong diagnosis
Ask ten people in an open-plan office what bothers them and nine will say noise. Push a little further and the real complaint appears: not volume, but intelligibility. A loud air handler is annoying; a colleague’s sales call is corrosive, because your brain cannot stop parsing it. The distraction is not the sound level. It is the information.
That is why decibels alone are a poor specification. A space can be quiet and still have no speech privacy.
What STI measures
The Speech Transmission Index (STI) is a 0–1 scale, standardised in IEC 60268-16, for how much of a spoken signal survives the path between talker and listener. It accounts for background noise, reverberation and the geometry of the path together — the three things that actually decide whether a sentence arrives intact.
| STI | What a listener experiences |
|---|---|
| 0.75 – 1.00 | Excellent — near face-to-face clarity |
| 0.60 – 0.75 | Good — normal conversation is effortless |
| 0.45 – 0.60 | Fair — effort required, fatigue sets in |
| 0.20 – 0.45 | Poor — fragments only |
| below 0.20 | Effectively private |
The design target in an open office is not “a high STI everywhere”. It is two different STIs in two different places: high inside the work zone, below roughly 0.20 everywhere a third party is sitting. That gap is what people mean by speech privacy.
Why open plan fails by design
An open floor is a single acoustic volume. Every measure that helps one person hurts another: soft furnishings absorb some energy but do nothing about direct line-of-sight paths; white noise masks consonants and raises fatigue; distance helps until the room’s reverberation carries the rest. And the moment a hybrid meeting starts, one person on a video call becomes a broadcast station for the entire floor.
Where a pod changes the equation
An acoustic pod works differently from every other intervention, because it treats the problem at the source and at the receiver at the same time. It creates a second acoustic volume inside the first. The talker is enclosed, so the direct path is removed; the enclosure absorbs, so the reverberant path is shortened; and the listener outside is left with a muffled residue rather than a transcript.
What to look for in that enclosure:
- A measured insulation figure, to a named standard. The MAXipod Basic is specified as Class A acoustic insulation, 30 dB (D_S,A), tested to ISO 23351-1 — an enclosure-specific standard, not a generic material claim.
- Absorption inside, not just mass in the walls. Ours uses a 75 mm Class A absorber in a five-layer panel build. Insulation stops sound leaving; absorption stops the inside from becoming a resonant box.
- Ventilation that does not undo the seal. A pod that leaks air leaks sound. Two crossflow fans moving up to 390 m³/h, with automatic control, keep the airflow continuous without turning the shell into a sieve.
- A door that actually closes. Sealing lives in the details — a two-stage 60 kg door on a properly compressed gasket does more for privacy than an extra millimetre of panel.
What to ask any vendor
- Which standard, and which single-number quantity — D_S,A, D_w, or an unqualified “dB”?
- Is the figure for the enclosure or for a panel sample?
- Was it measured with ventilation running?
- What is the reverberation time inside?
- Can I see the report?
A vendor who can answer all five is selling engineering. A vendor who answers only the first is selling a brochure.
CTA: Bring your laptop and take a real call inside a MAXipod Basic. Book a demo.